Dell PowerEdge 2950 confusion

From NURDspace
Revision as of 20:39, 20 July 2016 by Dennis (talk | contribs) (→‎Todo)
Dell PowerEdge 2950 confusion
Confusion.jpg
Owner Space
Status Working
Hostname confusion
Location Server room
Tool No
Tool category

Dell PowerEdge 2950 confusion

Confusion.jpg {{{InventoryOwner}}}Property "Tool Owner" (as page type) with input value "{{{InventoryOwner}}}" contains invalid characters or is incomplete and therefore can cause unexpected results during a query or annotation process. Server room

Specs

  • 24GB fully buffered DDR2 (4x4GB and 4x2GB) Max is 32GB or 64GB for gen III
  • iDRAC @ [1]
  • CPU 2x X5450 Xeon 3GHz (4 cores each)
  • HDDs SAS 3x146GB and 3x73GB (264GB logical drive in OS)
  • 2 onboard network ports and 2x2 ports on cards. First port of one of the cards is currently connected (eth3).

The owners manual

OS

  • Proxmox 4, management on [2]

Network Layout

nurds-sw-04 port 12 set up to accept VLAN tagged packets.
eth3 connected to sw-04 port 12
bond0 set active-backup on connected eths (currently only eth3).
vmbr0 providing management console on VLAN1, bridging bond0 interface.
vmbr7 connected to VLAN7, bridging bond0.7 interface (i.e. tagging packets as VLAN7).
vmbr8 connected to VLAN8, bridging bond0.8 interface (i.e. tagging packets as VLAN8).
vmbr7 and vmbr8 available for VM/container binding, with no management interface connection.

Issues

  • Wake on LAN on connected NIC does't seem to work. I could not find the appropriate option in the BIOS
  • Console redirection in DRAC interface won't work with tried browsers and java

Todo

  • DRAC email alerts
  • Find out which generation server this is
  • Fix NFS mounts
  • Logins through LDAP
  • Add another network interface to the bond0 for failover (on another switch)
  • Seperate network interfaces for storage traffic?
  • move stuff from Precious to here (https://pve.proxmox.com/wiki/Convert_OpenVZ_to_LXC)