= Pew Laser = | = Pew Laser = | ||
Line 15: | Line 16: | ||
* 60x90 cm bed | * 60x90 cm bed | ||
* 90W CO2 Laser (dont run above ~70%) | * 90W CO2 Laser (dont run above ~70%) | ||
* | * ~10l of destilled water | ||
* CW-3000 water chiller | * CW-3000 water chiller | ||
== Todo == | == Todo == | ||
* | * fix outlet ground wire issue | ||
* | * fix cable management | ||
* | * replace laser tube | ||
* | * find a better spot for the water cooler | ||
* | * get a beam combiner for adjustment | ||
* level Z axis | |||
* find a way to get exhaust fumes out | |||
=== Stuff to get === | === Stuff to get === | ||
* new 90W 80mm laser tube | |||
* Hose for the exhaust (longer) | * Hose for the exhaust (longer) | ||
* beam combiner | |||
https://www.ebay.de/itm/Strahl-Combiner-Set-20mm-ZnSe-Laser-Beam-Combiner-Mount-Laser-Pointer-for-Tube/123538714166?hash=item1cc37b2e36:m:mObdRbejltnroRBy97ITT4g:rk:31:pf:0 | |||
* chaos chaotically ordered a PSU on 2016/04/27(or around) to replace the broken one ; http://www.aliexpress.com/snapshot/7615321008.html?orderId=74879451300975 | * chaos chaotically ordered a PSU on 2016/04/27(or around) to replace the broken one ; http://www.aliexpress.com/snapshot/7615321008.html?orderId=74879451300975 | ||
Line 44: | Line 47: | ||
=== Electrical problems === | === Electrical problems === | ||
* <s>Hook up ground</s> The machine's ground is wired internally to the euro socket, so no need for external ground. | * <s>Hook up ground</s> The machine's ground is wired internally to the euro socket, so no need for external ground. | ||
** Unless there is no ground on the socket so when connecting the ground must be checked. | ** Unless there is no ground on the socket so when connecting the ground must be checked. |
Revision as of 13:42, 20 January 2019
Lasercutter | |
---|---|
Owner | Jglauche |
Status | Broken |
Tool | Yes |
Tool category | Fabrication |
Jinan-lasercutter.jpg {{{InventoryOwner}}}Property "Tool Owner" (as page type) with input value "{{{InventoryOwner}}}" contains invalid characters or is incomplete and therefore can cause unexpected results during a query or annotation process. {{{Location}}}Property "Tool Location" (as page type) with input value "{{{Location}}}" contains invalid characters or is incomplete and therefore can cause unexpected results during a query or annotation process.
IMPORTANT: The content of this section is outdated. Please update this section if you can. If you have checked or updated this section and found the content to be suitable, please remove this notice. |
Pew Laser
Specifications
- Class IV
- 60x90 cm bed
- 90W CO2 Laser (dont run above ~70%)
- ~10l of destilled water
- CW-3000 water chiller
Todo
- fix outlet ground wire issue
- fix cable management
- replace laser tube
- find a better spot for the water cooler
- get a beam combiner for adjustment
- level Z axis
- find a way to get exhaust fumes out
Stuff to get
- new 90W 80mm laser tube
- Hose for the exhaust (longer)
- beam combiner
- chaos chaotically ordered a PSU on 2016/04/27(or around) to replace the broken one ; http://www.aliexpress.com/snapshot/7615321008.html?orderId=74879451300975
Exhaust fumes extraction problem
Options:
- Remove window above hallway door, replace with wood. mount pipe onto wood.
- Cut hole in door, fit pipe over hole in door
- Cut hole in air duct, mount pipe over hole
- Decide on coarse filter, as the supplied filter will clog if use without.
- Open door and toss out hose when in use. Revert when done.
Electrical problems
Hook up groundThe machine's ground is wired internally to the euro socket, so no need for external ground.- Unless there is no ground on the socket so when connecting the ground must be checked.
10/4 Laser cutter does not give output power anymore after first successful test run. no high frequent buzzing anymore one should expect. Only what appears the sounds of sparks on first fire. then nothing.
16/4 Opened up laser power supply (I know what I am doing) (famous last words) and it appears the flyback transformer is toast. the secondary of the transformer measures fully open. (or the resistance is >30 M Ohm)
Also the power supply appears to be a 80 W model whereas we have a 90W tube. Thoughts ?
2 options.
- get new power supply. about €200 ish
- get new flyback transformers and just hope it works. This is the cheaper option.
Power rating is 90W. Tube length is 120 cm.