Nexia PM

From NURDspace
Revision as of 00:56, 29 April 2017 by Danieltoo (talk | contribs)
NURDs Inventory
NEXIA PM.jpg
Owner Space
Status Infrastructure
Hostname nexia.nurdspace.lan
Location Small 19" rack in the space
Tool
Tool category

{{{Name}}}Property "Tool Name" (as page type) with input value "{{{Name}}}" contains invalid characters or is incomplete and therefore can cause unexpected results during a query or annotation process.

NEXIA_PM.jpg {{{InventoryOwner}}}Property "Tool Owner" (as page type) with input value "{{{InventoryOwner}}}" contains invalid characters or is incomplete and therefore can cause unexpected results during a query or annotation process. Small 19" rack in the space

This is a digital mixing panel with lots of inputs and outputs. Currently it has 3 channels open:

These are mixed and outputted to 2 Altec Lansing 9444A amplifiers at the bottom of the rack.

Making changes to the configuration can be done via the windows software which also runs fine in Wine under Linux. The key is to connect to the Nexia, then disconnect from it, edit the configuration and then upload it again. When in doubt, save the old config first!

IP address has been set to 10.208.30.13 (20170429) to be within the same network as the rest of the space.

To connect with the software, change your static IP to 192.168.1.100. Go to Tools, Options, Network. Press Select NIC and select the configured network controller.

The device also has a telnet interface. One example command:

echo 'GET 1 IPADDR' |nc nexia 23

More info on Telnet commands: File:Nexia_RS232_Control_(Jan10).pdf

Links

http://www.biamp.com/products/nexia/nexia_pm.aspx