Lasercutter

From NURDspace
Revision as of 13:42, 20 January 2019 by Jglauche (talk | contribs)
Lasercutter
Jinan-lasercutter.jpg
Owner Jglauche
Status Broken
Tool Yes
Tool category Fabrication

Lasercutter

Jinan-lasercutter.jpg {{{InventoryOwner}}}Property "Tool Owner" (as page type) with input value "{{{InventoryOwner}}}" contains invalid characters or is incomplete and therefore can cause unexpected results during a query or annotation process. {{{Location}}}Property "Tool Location" (as page type) with input value "{{{Location}}}" contains invalid characters or is incomplete and therefore can cause unexpected results during a query or annotation process.

Pew Laser

Specifications

  • Class IV
  • 60x90 cm bed
  • 90W CO2 Laser (dont run above ~70%)
  • ~10l of destilled water
  • CW-3000 water chiller

Todo

  • fix outlet ground wire issue
  • fix cable management
  • replace laser tube
  • find a better spot for the water cooler
  • get a beam combiner for adjustment
  • level Z axis
  • find a way to get exhaust fumes out


Stuff to get

  • new 90W 80mm laser tube
  • Hose for the exhaust (longer)
  • beam combiner

https://www.ebay.de/itm/Strahl-Combiner-Set-20mm-ZnSe-Laser-Beam-Combiner-Mount-Laser-Pointer-for-Tube/123538714166?hash=item1cc37b2e36:m:mObdRbejltnroRBy97ITT4g:rk:31:pf:0

Exhaust fumes extraction problem

Options:

  • Remove window above hallway door, replace with wood. mount pipe onto wood.
  • Cut hole in door, fit pipe over hole in door
  • Cut hole in air duct, mount pipe over hole
  • Decide on coarse filter, as the supplied filter will clog if use without.
  • Open door and toss out hose when in use. Revert when done.

Electrical problems

  • Hook up ground The machine's ground is wired internally to the euro socket, so no need for external ground.
    • Unless there is no ground on the socket so when connecting the ground must be checked.

10/4 Laser cutter does not give output power anymore after first successful test run. no high frequent buzzing anymore one should expect. Only what appears the sounds of sparks on first fire. then nothing.

16/4 Opened up laser power supply (I know what I am doing) (famous last words) and it appears the flyback transformer is toast. the secondary of the transformer measures fully open. (or the resistance is >30 M Ohm)

Also the power supply appears to be a 80 W model whereas we have a 90W tube. Thoughts ?

2 options.

  • get new power supply. about €200 ish
  • get new flyback transformers and just hope it works. This is the cheaper option.

Power rating is 90W. Tube length is 120 cm.

link to manufacturer website

Laser tube label.jpg

Manual