Electricity overhaul: Difference between revisions
Septillion (talk | contribs) No edit summary |
Septillion (talk | contribs) |
||
| (9 intermediate revisions by the same user not shown) | |||
| Line 10: | Line 10: | ||
|Image=File:danger-high-voltage-sign-vector-6149863.jpg | |Image=File:danger-high-voltage-sign-vector-6149863.jpg | ||
}} | }} | ||
This page is to make some investigate and track the changes that could/need to be done or are done, keeping in mind that we also would like [[Solar power]]. | This page is to make some investigate and track the changes that could/need to be done or are done, keeping in mind that we also would like [[Solar power]]. | ||
| Line 18: | Line 17: | ||
== Stuff that needs to happen == | == Stuff that needs to happen == | ||
* <s>Replace the current [[groepenkast]]</s> | * <s>Replace the current [[groepenkast]]</s> | ||
* Rebuild whole infra | * Add 'kabelgoot' | ||
* Add more groups | * Rebuild whole infra (step by step) | ||
* Remove old infra | * <s>Add more groups</s> | ||
* upgrade aansluiting | * Remove old infra (as we go) | ||
* upgrade aansluiting to 3x25A | |||
== Ideas == | |||
What do we like to achieve in the end: | |||
* Done! <s>One distribution board for the whole space @ grid connection point</s> | |||
* Done! <s>[https://en.wikipedia.org/wiki/Residual-current_device#RCBO2 RCBO] (Dutch: [https://nl.wikipedia.org/wiki/Aardlekautomaat aardlekautomaat]) for every end circuit to isolate circuits for each other.</s> | |||
* Replace all wiring | |||
* New wiring in central cable tray along the length of the space | |||
* Go step by step, old distribution stays in place until room is remodeled | |||
* Upgrade to 3-phase power | |||
== Original layout == | == Original layout == | ||
| Line 32: | Line 41: | ||
== Original circuits == | == Original circuits == | ||
=== | Called "groepen" in Dutch. | ||
=== Groepen kast A=== | |||
{| class="wikitable" | {| class="wikitable" | ||
|- | |- | ||
| Line 52: | Line 62: | ||
|} | |} | ||
=== | === Groepen Kast B=== | ||
{| class="wikitable" | {| class="wikitable" | ||
|- | |- | ||
| Line 59: | Line 69: | ||
! Description | ! Description | ||
|- | |- | ||
| Groep 1 | | <del>Groep 1</> | ||
| zaal 3 zaal2 gang 1 wcd | | zaal 3 zaal2 gang 1 wcd | ||
| 16 A | | 16 A | ||
| Line 71: | Line 81: | ||
|- | |- | ||
|} | |} | ||
Groep 1 is now out of service as part of the overhaul. | |||
== New == | == New == | ||
=== | See [[Distribution board#Circuits]] | ||
== 3-phase power == | |||
Currently the space is supplied with 1-phase power. It is a 1x30A (or maybe even a 1x25A) connection. Now the [[distribution board]] is upgraded and has a 4-pole main switch (Dutch: hoofdschakelaar) it is possible to apply for an upgrade to 3-phase. This would mean an upgrade to 3x25A. The monthly fee is the same as the current 1-phase. | |||
The upgrade needs to be applied from Liander via [https://www.mijnaansluiting.nl]. The cost is [https://www.liander.nl/-/media/files/tarieven/consument/2024/eenmalige-tarieven-stroom-2024.pdf €332,15] and is expected tot take 6 weeks. The smart meter will get replaced in the process. | |||
== Old ideas == | == Old ideas == | ||
| Line 252: | Line 200: | ||
|- | |- | ||
| | | | ||
|} | |||
=== New circuits idea === | |||
{| class="wikitable" | |||
|- | |||
! Name | |||
! Location | |||
! Description | |||
|- | |||
| light incl. emergency light. | |||
| whole space. | |||
| 1 | |||
|- | |||
| serverrack. | |||
| hall. | |||
| 2 | |||
|- | |||
| Cv. installation. | |||
| cv. closet. | |||
| 3 | |||
|- | |||
| Dishwasher. refrigerator incl. beer. | |||
| bar. | |||
| 4 | |||
|- | |||
| Cooker | |||
| bar. | |||
|6 | |||
|- | |||
| Furness | |||
| 2X16A or 3x16A | |||
| 7 | |||
|- | |||
|General Usage | |||
| bar. | |||
|8 | |||
|- | |||
|room1. | |||
| room 1. | |||
|9 | |||
|- | |||
| room 1 | |||
| room1. | |||
| 10 | |||
|- | |||
| room 2 | |||
| | |||
| 11 | |||
|- | |||
|room 2 | |||
| | |||
| 12 | |||
|- | |||
| room 3 | |||
| room 3. | |||
| 13 | |||
|- | |||
| room 3 | |||
| room 3. | |||
| 14 | |||
|- | |||
| Maker corner 1 | |||
| maker corner. | |||
| 15 | |||
|- | |||
| Solar panels | |||
| rooftop | |||
|16 | |||
| What is nessary (Rubberduck has 2X16 A for it) | |||
|- | |||
|} | |} | ||
Latest revision as of 20:56, 9 April 2025
| Electricity overhaul | |
|---|---|
| Participants | Septillion |
| Skills | |
| Status | In progress |
| Niche | Electronics |
| Purpose | Infra |
| Tool | No |
| Location | Space |
| Cost | |
| Tool category | Infra |
Electricity overhaul Property "Tool Image" (as page type) with input value "File:{{{Picture}}}" contains invalid characters or is incomplete and therefore can cause unexpected results during a query or annotation process. {{{Picture}}} {{#if:No | [[Tool Owner::{{{ProjectParticipants}}} | }} {{#if:No | [[Tool Cost::{{{Cost}}} | }}
This page is to make some investigate and track the changes that could/need to be done or are done, keeping in mind that we also would like Solar power.
This page is only for the project itself, see the pages about the distribution board and power distribution.
Stuff that needs to happen
Replace the current groepenkast- Add 'kabelgoot'
- Rebuild whole infra (step by step)
Add more groups- Remove old infra (as we go)
- upgrade aansluiting to 3x25A
Ideas
What do we like to achieve in the end:
- Done!
One distribution board for the whole space @ grid connection point - Done!
RCBO (Dutch: aardlekautomaat) for every end circuit to isolate circuits for each other. - Replace all wiring
- New wiring in central cable tray along the length of the space
- Go step by step, old distribution stays in place until room is remodeled
- Upgrade to 3-phase power
Original layout
Original circuits
Called "groepen" in Dutch.
Groepen kast A
| Name | Location | Description |
|---|---|---|
| Groep 4 Kast A | Toilet groep bar | 16 A |
| Groep 5 res. | ||
| 3 fase groep | voeding kast b | 3x 20A afgezekerd. |
Groepen Kast B
| Name | Location | Description |
|---|---|---|
| zaal 3 zaal2 gang 1 wcd | 16 A | |
| Groep 2 res. | Zaal 2 zaal3 1 wcd, gang deur makershoek zaal 1 studio | |
| groep 3 | zaal 3 bar makershoek |
Groep 1 is now out of service as part of the overhaul.
New
See Distribution board#Circuits
3-phase power
Currently the space is supplied with 1-phase power. It is a 1x30A (or maybe even a 1x25A) connection. Now the distribution board is upgraded and has a 4-pole main switch (Dutch: hoofdschakelaar) it is possible to apply for an upgrade to 3-phase. This would mean an upgrade to 3x25A. The monthly fee is the same as the current 1-phase.
The upgrade needs to be applied from Liander via [1]. The cost is €332,15 and is expected tot take 6 weeks. The smart meter will get replaced in the process.
Old ideas
Just moved here for reference.
Shopping list
I have made 2 different cabinet proposals. 1 with 2 columns and 1 with 1 column. File:kast_2kolom.pdf the 2 columns € 635.46 File:kast _1kolom.pdf the single. € 628.89 or we can make one ourselves, see the list belowNew circuits idea
| Name | Location | Description | |
|---|---|---|---|
| light incl. emergency light. | whole space. | 1 | |
| serverrack. | hall. | 2 | |
| Cv. installation. | cv. closet. | 3 | |
| Dishwasher. refrigerator incl. beer. | bar. | 4 | |
| Cooker | bar. | 6 | |
| Furness | 2X16A or 3x16A | 7 | |
| General Usage | bar. | 8 | |
| room1. | room 1. | 9 | |
| room 1 | room1. | 10 | |
| room 2 | 11 | ||
| room 2 | 12 | ||
| room 3 | room 3. | 13 | |
| room 3 | room 3. | 14 | |
| Maker corner 1 | maker corner. | 15 | |
| Solar panels | rooftop | 16 | What is nessary (Rubberduck has 2X16 A for it) |